Heat Pumps: How They Work and What to Stock

A heat pump is an air conditioner that can run in reverse to heat. This sheet explains the reversing valve, defrost and auxiliary heat, and the parts that are unique to heat pumps on a counter.

Ref HV-0005AHRI 210/24010 CFR 430

Draft, open for review. Check every value against the governing standard and the manufacturer’s data before use.

What it is

An air-source heat pump moves heat from outdoor air into the building in winter and from the building to outdoors in summer. A reversing valve switches the direction of refrigerant flow, so the outdoor coil acts as the condenser in cooling and as the evaporator in heating. Because the outdoor coil runs cold in heating mode, frost forms on it, and a defrost control periodically reverses the system to clear it. Auxiliary heat, usually electric heat strips in the air handler, adds heat when the heat pump alone cannot keep up and during defrost. Ratings are set under AHRI 210/240 and the DOE test procedures in 10 CFR 430.

How to identify

A heat pump outdoor unit has a reversing valve (a four-way valve with a solenoid coil) near the compressor and usually a defrost control board. The thermostat has heat pump settings and an "emergency heat" mode. The data plate says "heat pump" and lists both cooling and heating data.

Heat pump parts and what they do

PartFunctionStocking notes
Reversing valve and solenoid coilSwitches heating and coolingCoils are sold by voltage; valves by tonnage and connection size
Defrost control boardStarts and ends defrostOften brand specific; match the OEM part number
Defrost sensor or thermostatSenses outdoor coil temperatureClip-on style; match the board
Bi-flow filter drierFilters in both flow directionsStandard driers are one direction only
Bi-flow TXV or dual meteringMeters refrigerant in both modesPer OEM design
Heat strips (electric heat kits)Auxiliary and emergency heatSold by kW and air handler model
Sequencers or relaysStage heat stripsMatch the heat kit
Outdoor thermostat (on some systems)Locks out strips above a set pointOptional accessory
Heat pump thermostatControls O or B valve terminal, aux and emergency heatConfirm O or B before selling

Key points

  • Thermostat terminal O energizes the reversing valve in cooling. Terminal B energizes it in heating. Brands differ. Wiring the wrong one makes the system heat when it should cool.
  • Auxiliary heat (W2) comes on automatically as a second stage. Emergency heat (E) runs the strips and shuts off the heat pump.
  • Steam or fog from the outdoor unit during defrost is normal.
  • Cold-climate heat pumps keep more capacity at low outdoor temperatures. Compare published capacity data at the temperatures that matter.

Common mistakes

  • Selling a standard one-way filter drier for a heat pump line.
  • Setting the thermostat for B on a system that uses O.
  • Treating the emergency heat light as a fault code.
  • Replacing a defrost board with a "universal" board without matching the sensor and timing settings.

Governing standards: AHRI 210/240; 10 CFR 430 (DOE energy conservation program for consumer products); manufacturer installation instructions.

Reference only. Verify against the current governing code or standard, the manufacturer's data and the project documents before use. Apps for Distributors disclaims liability arising from reliance on this reference.

Suggest an edit

This library is written in the open, like a wiki: anyone can suggest a correction or an addition, and each change is checked against the source before it goes live.

Know this subject well? Volunteer to review or write sheets.

← All HVAC sheets

Your catalog, your prices and your name, on every customer’s phone.

Same app, same scanner, works with your existing ERP. Loaded with your catalog and your logo.